English
Espanol


 

Sitemap | Contact 
 

Global Excellence

Why TESCA ?
  Available Inventory
  On-Time Delivery
  Competitive Prices
  Quality Product
  Rapid Response

 




NDT

Ultrasonic Flaw Detector TUD210
Product Photo
  Features  

●Real-time multi function system, stable, reliable and efficient operation
●The embedded software can be updated online
●Big memory of 400 A graph and 40000 thickness value
●Super Fast sampling capability, RF wave full display
●Wide & high bright EL display screen
●Alternative switch between single probe and double  probe
●DAC automatically creation with standard test block
●Li battery, continue working time up to 6 hours
●USB and RS232 interface
●Adjustability of DAC curve is available for various requirements  of DAC application
●High speed sampling, radio frequency display with 80 MHz for sampling Min. display range 2.5mm

Technical Specification

Test modes

Pulse-echo and dual

Pulse

Spike excitation pulse

Measuring range

2.5mm to 5000mm / 0.1inch to 200 inch

Sound speed

1000 m/s~9999m/s

Vertical linearity error

≤3%

Dynamic range

≥32dB

Horizontal linearity error

≤0.2%

Display delay

-20μs to +3400μs

Sensitivity leavings

≥50dB

Pulse displacement

-20~+3400 μ s

Probe delay

0μs~99.99μs, resolution 0.01

Gain

0-110 dB variable in selectable steps of 0.2,0.5 ,1,2,6,12, and locked

Damping

50 ohms, 150 ohms, and 400 ohms

Rectification

Full wave, positive half wave, negative half wave and RF

Bandwidth

0.2MHz~10MHz (Low0.2~1, Mid.0.5~4, High 2~10)

Reject

Linear, 0-80% of full screen, variable in steps of 1%

Scanning Resolution

0.1mm (2.5mm ~100mm)     1mm (100 mm ~5000mm)

Display screen

320×240 pixels

Distance readout

Provide single echo or echo to echo thickness reading or sound path, surface, and depth reading for angle beam testing with either peak or flank detection.

Unit

mm/inch

Interface

RS 232 and USB interface 9600 baud, 8 bits word length, no parity, 1 stop bit

Printer driver

TP UP-NH-S thermal printer

Power supply

Li batteries, continues working time approx. 6 hours

AC requirements

85 to 264V AC/1.0A, 47 to 63Hz

Charging time

5 hours maximum

Operating temperature

0 ℃ to +40℃

Storage temperature

-20℃ to+60℃

Dimensions (D×W×H)

53 mm×184 mm×230 mm

Weight

1.2 kg

Probe connector

LEMO

 
 

Standard delivery

Optional accessary
 
  • Main unit                                          
  • Li battery                                          
  • Neck strap                                        
  • Power adapter               
  • Couplant                                            
  • Straight transducer  
  • Angle transducer
  • Cable with LEMO connector              
  • Protection pocket                        
  • Screwdriver           
  • TIME certificate                                 
  • Warranty card                                    
  • Connecting cable                       
  • Printer TP UP-NH           
  • Dataview software for TUD210                                
  • Various
Optional Ultrasonic Transducers
TIME supplies various kinds of ultrasonic probes as customer's requirements

Dataview software

   

 